Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Paper Recorders

DR4300 Circular Chart Recorder

DR4300 records process measurements on a ten-inch circular paper chart using one or two pens.

DR4300 records process measurements on a ten-inch circular paper chart using one or two pens. Published arrangements include versions with or without a digital display, with control and alarm functions available for suitable duties. It accepts signals for temperature, humidity, pressure or flow and targets batch processes such as ovens, chambers and industrial production equipment.

Models: DR4300

Features & Benefits

Chart
10-inch circular
Pens
One or two

Applications

  • Batch-process recording
  • Ovens and environmental chambers
  • Food and pharmaceutical equipment

Detailed capabilities

What Is It?

DR4300 is described as a 10-inch, one- or two-pen recorder using preprinted charts and fiber-tip pens, with display and nondisplay variants. The source gives different typical accuracy/calibration statements for those variants and offers PID/alarm capability. These DR4300 facts must remain separate from the later operating paragraph, which switches to generic Truline wording.

Manufacturer reference ↗

How Does It Work?

The product-specific introduction describes a preprinted-chart recorder, but the source's operating subsection describes Truline chart generation and hot-stylus alternatives. This apparent reuse is retained as a documentation conflict rather than asserting that every DR4300 prints its own chart. The same caution applies to generic display, keypad and front-protection statements until matched to the exact DR4300 configuration.

Manufacturer reference ↗

What Problems Does It Solve?

The stated DR4300 role is economical recording of one or two process variables in batch and industrial equipment. Temperature, humidity, pressure and flow sources can be represented according to the selected input. The recorder's own chart/pen and variant documentation should determine consumables and maintenance, avoiding an unsupported merger with the DR4500/Truline description.

Manufacturer reference ↗

Specifications

Electrical Specifications

Alarm Outputs
Up to 2 SPDT Relays or Open Collector Outputs
Transmitter Power
24 VDC, 100 mA Max
Output Type
Electromechanical Relay, Open Collector, 4 to 20 mA Current Output
Input Impedance
mA: 250 Ω, V: 200 kΩ, RTD: 13.3 kΩ, Others: 10 MΩ

Processing & Performance Metrics

Sampling rate
Every 0.33 sec

Environmental Conditions

Relative Humidity
10 to 90% RH (derated above 40 deg C)
Operating Temperature Range
15 to 55 deg C (max 50 deg C for UL listing)

Applications & Compatibility

Mounting
Panel, Surface, or 2 in Pipe

I/O Capabilities

Inputs
1 (Single Pen) or 2 (Dual Pen); Thermocouples, RTDs, mA, mV, V
Control Modes
Manual, Automatic (local setpoint)

Mechanical & Physical Properties

Chart Size
10.24 in (260 mm) Diameter, 4 in (100 mm) Calibrated Width

Standards & Certifications

Approvals
CE, UL, CSA
DR4300 Circular Chart Recorder — manufacturer page values
ParameterPublished value / configuration
Alarm OutputsUp to 2 SPDT Relays or Open Collector Outputs
Transmitter Power24 VDC, 100 mA Max
Output TypeElectromechanical Relay, Open Collector, 4 to 20 mA Current Output
Input ImpedancemA: 250 Ω, V: 200 kΩ, RTD: 13.3 kΩ, Others: 10 MΩ
Sampling rateEvery 0.33 sec
Relative Humidity10 to 90% RH (derated above 40 deg C)
Operating Temperature Range15 to 55 deg C (max 50 deg C for UL listing)
MountingPanel, Surface, or 2 in Pipe
Inputs1 (Single Pen) or 2 (Dual Pen); Thermocouples, RTDs, mA, mV, V
Control ModesManual, Automatic (local setpoint)
Chart Size10.24 in (260 mm) Diameter, 4 in (100 mm) Calibrated Width
ApprovalsCE, UL, CSA

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Published part numbers

10 parts

Part NumberDescriptionEnquiry
22996BALUN FERRITE BEAD AXIALRequest quotation
24001660-00110 IN CIRCULAR CHART-STOCKRequest quotation
24001660-00210 IN CIRCULAR CHART-STOCKRequest quotation
24001660-00310 IN CIRCULAR CHART-STOCKRequest quotation
24001660-00410 IN CIRCULAR CHART-STOCKRequest quotation
24001660-00510 IN CIRCULAR CHART-STOCKRequest quotation
24001660-00610 IN CIRCULAR CHART-STOCKRequest quotation
24001660-00710 IN CIRCULAR CHART-STOCKRequest quotation
24001660-00810 IN CIRCULAR CHART-STOCKRequest quotation
24001660-00910 IN CIRCULAR CHART-STOCKRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/process-instruments/recorders/paper-recorders/dr4300-circular-chart-recorder

Last source check: 2026-11-02

DR4300 Circular Chart Recorder Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry