Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Actuators

HercuLine Electric Actuators

HercuLine actuators position dampers and quarter-turn valves using electric rotary drives.

HercuLine actuators position dampers and quarter-turn valves using electric rotary drives. The portfolio includes low-torque 2000-series units and higher-torque 10260 arrangements, with enhanced electronics available on relevant versions. Programmable settings, non-contact position sensing and communication options support commissioning and integration for continuous industrial service, including furnace, combustion-air and coal-mill damper applications.

Models: 10260 Series, 2000 Series, 2001/2002 Series

Features & Benefits

Families
HercuLine 2000 and 10260
Functions
Programmable positioning and non-contact feedback
  • Simplifies configuration and plant integration

Applications

  • Dampers
  • Quarter-turn valves
  • Furnace and combustion-air control

Detailed capabilities

What Is It?

HercuLine 2000 covers low-torque damper and quarter-turn valve work, while 10260A addresses the stated medium-torque range. 10260S adds the microprocessor-based EEU for continuous-duty applications such as furnace, windbox and coal-mill dampers or gas/air valves. Torque values use different units across these groups and must remain attached to the corresponding series.

Manufacturer reference ↗

How Does It Work?

Programmable electronics and noncontact position sensing provide the stated repeatability and rapid start/stop behavior. RS485/Modbus RTU and the described HART integration permit parameter access through maintenance/control networks, with HercuLink available. Relays can indicate temperature limits, stall, input-signal loss or position-sensor failure, making diagnostic assignments configurable rather than identical on every output.

Manufacturer reference ↗

What Problems Does It Solve?

Repeatable positioning reduces overshoot and response delay in driven valves/dampers, while diagnostics expose conditions that would otherwise interrupt control. The source links continuous-duty reliability and reduced upkeep with lower lifetime cost. Those benefits depend on choosing the proper torque, series, interface and mechanical load rather than selecting a motor only by the common HercuLine name.

Manufacturer reference ↗

Specifications

Applications & Compatibility

Applications
Butterfly/Rotary Valves; Dampers; Diagnostics; Remote Setpoint

I/O Capabilities

Stroke Time (Full Travel)
10 to 60 sec/90 deg at 60 Hz (10260 Series); 6 to 75 sec/150 deg at 60 Hz (2000, 2001/2002 Series)
Position Sensing
Non-Contact (digital); Slidewire (basic)

Measurement & Sensor Related (Measurement Capabilities)

Repeatability
0.2% of span (2001/2002 Series, 10260 Series)

Environmental Conditions

Relative Humidity
0 to 99% RH (Non-Condensing)
Operating Temperature Range
-20 to 170 deg F (10260A: 185 deg F) (10260 Series); -40 to 170 deg F (2001/2002 Series); -40 to 185 deg F (2000 Series)

Electrical Specifications

Power Input
100 to 130/200 to 240 VAC voltage direct current
Output Torque
10 to 300 lb.ft. (10260 Series); 50 to 400 in.lb. (2000, 2001/2002 Series)
Motor
Instant start/stop, stall for 100 hrs, non-burnout, continuous duty

Overview

Models
10260 Series; 2000 Series; 2001/2002 Series

Communication & Protocols

Communication
HART/Modbus RTU
HercuLine Electric Actuators — manufacturer page values
ParameterPublished value / configuration
ApplicationsButterfly/Rotary Valves; Dampers; Diagnostics; Remote Setpoint
Stroke Time (Full Travel)10 to 60 sec/90 deg at 60 Hz (10260 Series); 6 to 75 sec/150 deg at 60 Hz (2000, 2001/2002 Series)
Position SensingNon-Contact (digital); Slidewire (basic)
Repeatability0.2% of span (2001/2002 Series, 10260 Series)
Relative Humidity0 to 99% RH (Non-Condensing)
Operating Temperature Range-20 to 170 deg F (10260A: 185 deg F) (10260 Series); -40 to 170 deg F (2001/2002 Series); -40 to 185 deg F (2000 Series)
Power Input100 to 130/200 to 240 VAC voltage direct current
Output Torque10 to 300 lb.ft. (10260 Series); 50 to 400 in.lb. (2000, 2001/2002 Series)
MotorInstant start/stop, stall for 100 hrs, non-burnout, continuous duty
Models10260 Series; 2000 Series; 2001/2002 Series
CommunicationHART/Modbus RTU

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Published part numbers

10 parts

Part NumberDescriptionEnquiry
005791P C ASSEMRequest quotation
00964010260 FIBER GEAR & BEARINGRequest quotation
00964110268/9 GEAR & BEARINGRequest quotation
009783GEAR MOTOR PINIONRequest quotation
009939WIDE HEAVY MOTOR GEARRequest quotation
009941SMALL METAL MOTOR GEARRequest quotation
013814POT TRIM 10KOHM 10% 0.5W 1TRequest quotation
017881MOTOR 420 OZ. IN.Request quotation
017883MOTOR 220 OZ.IN.Request quotation
019367CHOKE 100 MICROHENRY 3 OHMRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/process-instruments/actuators/herculine-electric-actuators

Last source check: 2026-11-02

HercuLine Electric Actuators Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry