Safety Systems
Fail Safe Controller
Fail Safe Controller is Honeywell's discontinued first-generation safety platform; the source states that new systems are no longer sold and identifies Safety Manager as its replacement.
Fail Safe Controller is Honeywell's discontinued first-generation safety platform; the source states that new systems are no longer sold and identifies Safety Manager as its replacement. The QMR-based controller supported protective functions such as shutdown, burner management and machinery safeguarding. The page retains spares information for installed equipment, making this a legacy-system reference rather than a new-system offer.
Features & Benefits
- Lifecycle
- Discontinued
- Supports reference and maintenance of installed legacy systems
Applications
- Installed FSC safety and shutdown systems
Detailed capabilities
Product and configuration
Fail Safe Controller is Honeywell's discontinued first-generation safety platform; the source states that new systems are no longer sold and identifies Safety Manager as its replacement. The QMR-based controller supported protective functions such as shutdown, burner management and machinery safeguarding. The page retains spares information for installed equipment, making this a legacy-system reference rather than a new-system offer.
- Lifecycle: Discontinued
Operation and integration
FSC uses QMR-based redundant control for safety and shutdown functions integrated with TPS/UCN. Peer communication links it to Process Manager variants and Logic Manager, while higher-level applications can use LCN connections. A separate safety network can isolate emergency shutdown logic from process-control strategies.
Application and selection
The manufacturer states FSC is discontinued and replaced by Safety Manager, with spares still available. Its retained applications include burner management, safeguarding, fire/gas and pipeline monitoring. Installed-base support and migration should reflect this lifecycle status.
Others
- Standards
- EN 61511-1:2017/A1:2017; IEC 61508-1:2010 (SIL 1-3); IEC 61508-2:2010 (SIL 1-3); IEC 61508-3:2010 (SIL 1-3); SIL 3; TUV Certified
| Parameter | Published value / configuration |
|---|---|
| Standards | EN 61511-1:2017/A1:2017; IEC 61508-1:2010 (SIL 1-3); IEC 61508-2:2010 (SIL 1-3); IEC 61508-3:2010 (SIL 1-3); SIL 3; TUV Certified |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 10006/2/1 | DIAGNOSTIC AND BATTERY MODULE (DBM) CC | Request quotation |
| 10100/2/1 | HORIZONTAL BUS DRIVER (HBD) CC | Request quotation |
| 10101/2/1 | SAFE DI MODULE 24 VDC 16CH CC | Request quotation |
| 10101/2/3 | SAFE DI MODULE 48 VDC 16CH CC | Request quotation |
| 10101/A/1 | ADAPTER NO DI WITH ELD FUNCTION 16CH | Request quotation |
| 10102/2/1 | SAFE AI MODULE 4CH CC | Request quotation |
| 10102/A/1 | 10102/A/1CC CONV. 0(4)-20 MA INT.POWER | Request quotation |
| 10102/A/2 | 10102/A/2CC CONV. 0(4)-20 MA EXT.POWER | Request quotation |
| 10102/A/3 | 10102/A/3CC CONVERTER 0(1)-5 V | Request quotation |
| 10102/A/4 | 10102/A/4CC CONVERTER 0(2)-10 V | Request quotation |
Manufacturer sources
https://process.honeywell.com/us/en/products/process-automation/safety-systems/fail-safe-controller
Last source check: 2026-11-02
Fail Safe Controller Cabinet Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.