Modular Controllers
ControlEdge™ PLC
ControlEdge PLC connects process and business applications through an open controller platform with embedded cybersecurity.
ControlEdge PLC connects process and business applications through an open controller platform with embedded cybersecurity. OPC UA and other supported interfaces simplify integration, while Universal I/O supports remote configuration and later signal changes. Using a common Experion operator interface can reduce additional stations and training, making the platform suitable for balance-of-plant and wider industrial automation duties.
Features & Benefits
- Integration
- OPC UA and Experion
- I/O
- Universal I/O configuration
- Reduces integration hardware and operator-interface duplication
Applications
- Balance-of-plant automation
- Industrial PLC applications
Detailed capabilities
Product and configuration
ControlEdge PLC connects process and business applications through an open controller platform with embedded cybersecurity. OPC UA and other supported interfaces simplify integration, while Universal I/O supports remote configuration and later signal changes. Using a common Experion operator interface can reduce additional stations and training, making the platform suitable for balance-of-plant and wider industrial automation duties.
- Integration: OPC UA and Experion
- I/O: Universal I/O configuration
Operation and integration
ControlEdge PLC connects instruments and software through an open architecture including OPC UA. Universal I/O supports remote configuration and late signal-design changes under LEAP project execution. A common Experion HMI can reduce separate stations and duplicate hardware, licensing and training.
Application and selection
Secure boot, an embedded firewall and a certified secure development lifecycle form part of its cybersecurity approach. The platform supports standardized designs and scalable integration across plant and business levels, with controller, I/O and interface selection determined by the application.
Product videos
Standards & Certifications
- Approvals
- CE, UL, CSA, ATEX, IECEx, RCM, RoHS, ODVA, Marine (ABS, BV, DNV, KR, LR), ISASecure Level 2, RoHS Compliant
Processing & Performance Metrics
- User Programming Memory
- 10 MB (Program 5 MB, Data 5 MB), 256 MB/512 MB Flash (model dependent)
- Processor
- Dual Core ARM® Cortex™-A9, 667 MHz (32 bit)
- Maximum Expansion Racks
- 11 (Non-Redundant), 12 (Redundant)
- Maximum Digital Channels
- 4608
- Maximum Analog Channels
- 2304
I/O Capabilities
- Universal I/O
- HART-enabled, redundant/non-redundant, soft-configurable as AI/AO/DI/DO
- Time Sync
- SNTP, DNP3
- Maximum I/O Modules
- 144
- Integration
- Experion DCS, SCADA, FDM, OPC UA, Modbus, PROFINET, EtherNet/IP, MQTT, DNP3, HART-IP
- I/O Scan Time
- 10 to 3000 ms (adjustable)
- I/O Network Topology
- Star, Ring, DLR; Up to 100 m (Ethernet), 5 km (fiber MM), 40 km (fiber SM)
- I/O Modules
- Universal, Analog, Digital, Pulse/Frequency, Relay, High Level Analog, etc.
- Command Execution Time
- 85 µs per 1000 commands in Structured Text
Redundancy & Synchronization
- Switchover Time
- <100 ms
- Controller Redundancy
- Hot Standby supported
Communication & Protocols
- Serial Communication
- 2xRS232, 2xRS485, Modbus RTU/ASCII, User Defined Protocol, 6 modules per CPM
- Ethernet Ports
- 4 (RJ45, shielded, auto-crossover, 10/100BaseTx)
Memory & Storage
- SD Card Support
- Up to 32 GB (Class 6/10)
- RAM
- 256 MB/512 MB with ECC (model dependent)
Electrical Specifications
- Power Supply
- 51W 24VDC, 58W 110/240VAC, 41W 110/240VAC (Ext. Temp)
Environmental Conditions
- Operating Modes
- Run Locked, Stop Locked, Remote Running, Remote Stopped
- Mechanical Shock/Vibration
- 15 g, 11 ms, 6 Directions; IEC 60068-2-6, 3.5 mm/1 g, 10 cycles/axis
- Maximum Altitude
- 2000 meters
- Environmental
- -40 to +70 deg C (Extended Temp), 10 to 90% RH Non-Condensing, G3 Conformal Coating degree Celsius
Technical Specifications
- Non-Volatile Data Life
- 20+ years (no battery required)
Software & Interface
- Embedded Firewall/IPsec
- Supported on ports 1&2
Network & Connectivity Infrastructure
- Datalog Support
- Flash or SD Card, 1 ms Timestamp, Configurable Rate (1s to 1h)
Security & Access Control
- Cyber Security
- ISASecure EDSA Level 2 certified
Others
- Protocols Supported
- I/O Communication, EtherNet/IP Client, PROFINET (Ports 3&4); MODBUS TCP/UDP, OPC UA, HART-IP, CDA, EtherNet/IP Server, EUCN, DNP3, MQTT, IEC60870-5-104 (Ports 1&2)
| Parameter | Published value / configuration |
|---|---|
| Approvals | CE, UL, CSA, ATEX, IECEx, RCM, RoHS, ODVA, Marine (ABS, BV, DNV, KR, LR), ISASecure Level 2, RoHS Compliant |
| User Programming Memory | 10 MB (Program 5 MB, Data 5 MB), 256 MB/512 MB Flash (model dependent) |
| Processor | Dual Core ARM® Cortex™-A9, 667 MHz (32 bit) |
| Maximum Expansion Racks | 11 (Non-Redundant), 12 (Redundant) |
| Maximum Digital Channels | 4608 |
| Maximum Analog Channels | 2304 |
| Universal I/O | HART-enabled, redundant/non-redundant, soft-configurable as AI/AO/DI/DO |
| Time Sync | SNTP, DNP3 |
| Maximum I/O Modules | 144 |
| Integration | Experion DCS, SCADA, FDM, OPC UA, Modbus, PROFINET, EtherNet/IP, MQTT, DNP3, HART-IP |
| I/O Scan Time | 10 to 3000 ms (adjustable) |
| I/O Network Topology | Star, Ring, DLR; Up to 100 m (Ethernet), 5 km (fiber MM), 40 km (fiber SM) |
| I/O Modules | Universal, Analog, Digital, Pulse/Frequency, Relay, High Level Analog, etc. |
| Command Execution Time | 85 µs per 1000 commands in Structured Text |
| Switchover Time | <100 ms |
| Controller Redundancy | Hot Standby supported |
| Serial Communication | 2xRS232, 2xRS485, Modbus RTU/ASCII, User Defined Protocol, 6 modules per CPM |
| Ethernet Ports | 4 (RJ45, shielded, auto-crossover, 10/100BaseTx) |
| SD Card Support | Up to 32 GB (Class 6/10) |
| RAM | 256 MB/512 MB with ECC (model dependent) |
| Power Supply | 51W 24VDC, 58W 110/240VAC, 41W 110/240VAC (Ext. Temp) |
| Operating Modes | Run Locked, Stop Locked, Remote Running, Remote Stopped |
| Mechanical Shock/Vibration | 15 g, 11 ms, 6 Directions; IEC 60068-2-6, 3.5 mm/1 g, 10 cycles/axis |
| Maximum Altitude | 2000 meters |
| Environmental | -40 to +70 deg C (Extended Temp), 10 to 90% RH Non-Condensing, G3 Conformal Coating degree Celsius |
| Non-Volatile Data Life | 20+ years (no battery required) |
| Embedded Firewall/IPsec | Supported on ports 1&2 |
| Datalog Support | Flash or SD Card, 1 ms Timestamp, Configurable Rate (1s to 1h) |
| Cyber Security | ISASecure EDSA Level 2 certified |
| Protocols Supported | I/O Communication, EtherNet/IP Client, PROFINET (Ports 3&4); MODBUS TCP/UDP, OPC UA, HART-IP, CDA, EtherNet/IP Server, EUCN, DNP3, MQTT, IEC60870-5-104 (Ports 1&2) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 50008930-002 | Ethernet Switching Hub (16 ports) | Request quotation |
| 50008930-003 | ETHERNET SWITCH, 16 PORTS SINGLE MODE | Request quotation |
| 50008930-004 | ETHERNET SWITCH, 8 PORTS, SINGLE MODE | Request quotation |
| 50008930-008 | ETHRNT SWTCHG HUB 16PORT MULTI MODE G3,T | Request quotation |
| 50135395-001 | Ethernet to multi-mode Fiber Converter | Request quotation |
| 50135395-002 | ETHERNET TO SINGLE-MODE FIBER CONVERTER | Request quotation |
| 50135395-003 | ETHRNT TO MULTIMODE FIBER CONVERTER,G3,T | Request quotation |
| 50143176-100 | TRANSMITTER:STT650-T2-0-B-CH0-13S-A-00 | Request quotation |
| 50151665-001 | Primary-switched QUINT POWER supply | Request quotation |
| 51452262-503 | 900 IO MODULE INSERT LABEL KIT | Request quotation |
Manufacturer sources
https://process.honeywell.com/us/en/products/process-automation/modular-controllers/controledge-plc
Last source check: 2026-11-02
ControlEdge™ PLC Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.