Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Experion® LCN

Local Control Network (LCN)

Experion LCN provides a migration route from legacy TPS/LCN infrastructure into the Experion PKS architecture.

Experion LCN provides a migration route from legacy TPS/LCN infrastructure into the Experion PKS architecture. An ELCN bridge connects the coax network with Fault Tolerant Ethernet so nodes can be changed progressively. Retaining control strategies, field terminations, history and graphics helps plants modernize while managing disruption and preserving investment in the installed automation system.

Features & Benefits

Migration technology
ELCN bridge and Fault Tolerant Ethernet
  • Retains existing control and application investment during migration

Applications

  • TPS/LCN lifecycle modernization

Detailed capabilities

Product and configuration

Experion LCN provides a migration route from legacy TPS/LCN infrastructure into the Experion PKS architecture. An ELCN bridge connects the coax network with Fault Tolerant Ethernet so nodes can be changed progressively. Retaining control strategies, field terminations, history and graphics helps plants modernize while managing disruption and preserving investment in the installed automation system.

  • Migration technology: ELCN bridge and Fault Tolerant Ethernet

Manufacturer reference ↗

Operation and integration

An ELCN Bridge connects the Experion Fault Tolerant Ethernet infrastructure to an existing coaxial LCN. Conversion can proceed node by node, and a redundant bridge pair enables virtualization without a separate physical TPS-node connection for each node.

Manufacturer reference ↗

Application and selection

The migration preserves established strategies, field terminations, graphics, applications and history while modernizing the network. This incremental approach limits operational disruption and allows existing TPS investments to remain useful during a staged upgrade.

Manufacturer reference ↗

Case studies & further resources

Manufacturer Document

Experion Local Control Network Technical Specifications (EP03-390-501)

View resource ↗
Manufacturer Document

TotalPlant™ Solution Modernization: Experion Local Control Network

View resource ↗
Manufacturer Document

Control System Migration Surviving the "Perfect Storm" to Improve Performance

View resource ↗

Specifications

Others

Maximum Nodes per COAX Segment
40
Maximum Nodes (with extenders)
96
Maximum Nodes (no extenders)
64
Maximum Fiber Cable Length
2 km (via Switch SFP Ports)
Maximum ES-Ts per Cluster
30 (with conditions)
Maximum ELCN Bridge Pairs
1 per LCN
Maximum ESVT Clusters
5
Corrosive Environment
G4
Maximum Cable Length
100 m meter
Power Dissipation
12 W @ 80% Efficiency
Input Voltage
90 to 264 VAC voltage alternating current
Network Type
Fault Tolerant Ethernet
Navigation
5-Button Keypad
Key Switch
3-Positions (C: Configure, R1: Runtime 1, R2: Runtime 2)
Data Speed
100 Mbps (100Base-T)
Standards
CE; CSA; Korean EMC
Processor
XILINX INC XC7Z020-1CLG400I
MAU Power
Input Current - 50 mA (Typical), 70 mA (Max); Input Voltage - 3.3 VDC ±5%
LCD Type
4 Lines × 20 Characters
Series
Experion®
Memory
1G DDR3 SDRAM; 256 MB NOR FLASH
Local Control Network (LCN) — manufacturer page values
ParameterPublished value / configuration
Maximum Nodes per COAX Segment40
Maximum Nodes (with extenders)96
Maximum Nodes (no extenders)64
Maximum Fiber Cable Length2 km (via Switch SFP Ports)
Maximum ES-Ts per Cluster30 (with conditions)
Maximum ELCN Bridge Pairs1 per LCN
Maximum ESVT Clusters5
Corrosive EnvironmentG4
Maximum Cable Length100 m meter
Power Dissipation12 W @ 80% Efficiency
Input Voltage90 to 264 VAC voltage alternating current
Network TypeFault Tolerant Ethernet
Navigation5-Button Keypad
Key Switch3-Positions (C: Configure, R1: Runtime 1, R2: Runtime 2)
Data Speed100 Mbps (100Base-T)
StandardsCE; CSA; Korean EMC
ProcessorXILINX INC XC7Z020-1CLG400I
MAU PowerInput Current - 50 mA (Typical), 70 mA (Max); Input Voltage - 3.3 VDC ±5%
LCD Type4 Lines × 20 Characters
SeriesExperion®
Memory1G DDR3 SDRAM; 256 MB NOR FLASH

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
01-W2226E01ASCSI ADAPTERRequest quotation
30185-HESD KITRequest quotation
30669206-001C-AC100 SINGLE UNIRequest quotation
30669635-003TRIM STRIP, 48INRequest quotation
30669860-012O-Ring, AS568-006, EPDM, 50-DURRequest quotation
30671513-001TERM PANEL, HI-DEN C-TCB30Request quotation
30671529-001CABLE LCN HOOTER 3FTRequest quotation
30671529-002CABLE LCN HOOTER 7FTRequest quotation
30731391-001TERM PANEL AUX C-TAF00Request quotation
30731547-001BRKT ANGLE MNTGRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/process-automation/distributed-control-systems-dcs/experion-lcn/local-control-network-lcn

Last source check: 2026-11-02

Experion® LCN Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry