SmartLine Temperature Transmitters
SmartLine STT650
STT650 temperature transmitters mount on a DIN rail and offer compact arrangements for panels containing multiple measurement points.
STT650 temperature transmitters mount on a DIN rail and offer compact arrangements for panels containing multiple measurement points. Honeywell publishes RTD accuracy of 0.1°C, updates as fast as 135 ms, galvanic isolation and sensor diagnostics. Dual-channel options help reduce panel space and inventory while supporting stable temperature monitoring across process and ambient-temperature variations.
Models: STT650
Features & Benefits
- RTD accuracy
- 0.1°C
- Isolation
- 1500 VAC
- Reduces panel space for multiple measurements
Applications
- Panel-mounted temperature measurement
Product videos
Environmental Conditions
- Operating Temperature Range
- -40 to 85 deg C (-40 to 185 deg F)
- Relative Humidity
- 0 to 95% RH (Non-Condensing)
- Load Resistance
- Analog: ≤ (V - 8)/0.023 A, HART: ≤ (V - 7.2)/0.023 A
- Stability
- ±0.12% of span Over 2 years
I/O Capabilities
- Sensor Error Detection
- NAMUR NE43 Compliant
- Update/Response Time
- Analog Output: 135 ms, HART Output: 440 ms
- Galvanic Isolation
- 1500 VAC
- Configuration
- STT17C PC Configuration Tool (Windows XP/7/8/8.1, graphical UI, non-hazardous environments)
Processing & Performance Metrics
- Measurement Accuracy
- High Accuracy: 0.1 deg C for RTD, Stable Measurement (0.12% of span for two years)
Electrical Specifications
- Power Supply Effect
- ≤ 0.005% of span per VDC
- Supply Voltage
- 8 to 30 VDC (Intrinsically Safe); 8 to 35 VDC (Non-Intrinsically Safe)
- Output Options
- 4 to 20 mA Analog, HART® (v7.0)
- Input Type
- Universal Input: RTD (2, 3, 4 wire), Thermocouple (B, E, J, K, L, N, R, S, T, U, W3, W5, +Lr), Ohm, mV voltage direct current
Standards & Certifications
- Approvals
- CE Mark, IECEx, ATEX, CSA, FM Approvals (Intrinsic Safety, Non-Incendive, Dust Tight)
Applications & Compatibility
- Mounting
- DIN Rail, Compact Design
| Parameter | Published value / configuration |
|---|---|
| Operating Temperature Range | -40 to 85 deg C (-40 to 185 deg F) |
| Relative Humidity | 0 to 95% RH (Non-Condensing) |
| Load Resistance | Analog: ≤ (V - 8)/0.023 A, HART: ≤ (V - 7.2)/0.023 A |
| Stability | ±0.12% of span Over 2 years |
| Sensor Error Detection | NAMUR NE43 Compliant |
| Update/Response Time | Analog Output: 135 ms, HART Output: 440 ms |
| Galvanic Isolation | 1500 VAC |
| Configuration | STT17C PC Configuration Tool (Windows XP/7/8/8.1, graphical UI, non-hazardous environments) |
| Measurement Accuracy | High Accuracy: 0.1 deg C for RTD, Stable Measurement (0.12% of span for two years) |
| Power Supply Effect | ≤ 0.005% of span per VDC |
| Supply Voltage | 8 to 30 VDC (Intrinsically Safe); 8 to 35 VDC (Non-Intrinsically Safe) |
| Output Options | 4 to 20 mA Analog, HART® (v7.0) |
| Input Type | Universal Input: RTD (2, 3, 4 wire), Thermocouple (B, E, J, K, L, N, R, S, T, U, W3, W5, +Lr), Ohm, mV voltage direct current |
| Approvals | CE Mark, IECEx, ATEX, CSA, FM Approvals (Intrinsic Safety, Non-Incendive, Dust Tight) |
| Mounting | DIN Rail, Compact Design |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
1 parts
| Part Number | Description | Enquiry |
|---|---|---|
| STT650 | STT650 SMARTLINE TEMP. TRANSMITTER | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
SmartLine Temperature Transmitter STT650 image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.