Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

IoT Gas Sensors

Honeywell Versatilis™ Signal Scout™ Methane Sensor

Signal Scout detects methane using Microelectronic Spectroscopy.

Signal Scout detects methane using Microelectronic Spectroscopy. Honeywell publishes a battery-powered intrinsically safe version and an energy-harvesting version that adds photovoltaic panels and associated electronics. Both belong to the Versatilis sensing portfolio, with the choice of power arrangement supporting methane-leak detection duties across the oil and gas supply chain and safety applications.

Models: HVSS100

Features & Benefits

Variants
HVSS and HVSS-EH
Sensing technology
Microelectronic Spectroscopy

Applications

  • Methane leak detection
  • Oil and gas supply chain monitoring

Specifications

Technical Specifications

Methane Sensing Technology
Microelectronic Spectroscopy (MES)
Methane Concentration Range
50 to 65535 ppm
Methane Resolution
1 ppm
Methane Response Time (T90)
20 seconds with PTFE filter
Methane Accuracy
±50 ppm at 50–300 ppm; ±10% above 300 ppm (manufacturer's stated conditions)
Gas Sampling Rate
15 seconds
Operating Temperature
−40 to +70 °C (−40 to +158 °F)
Ambient Pressure Measurement
300 to 1100 hPa
Ambient Humidity Measurement
0 to 100% RH
Pressure Sensor Accuracy
0.5% of span
Humidity Sensor Accuracy
±3% RH
Wireless Configuration
2.4 GHz Bluetooth Low Energy 5.0
Long-Range Communication
LoRaWAN Class A; EU868, US915, IN865 and AS923 regions
LoRaWAN Activation
ABP or OTAA; Adaptive Data Rate supported
Electrical Supply
3.6 VDC ±5%
Electrical Consumption
1.5 mA, dependent on sensor duty cycle; 55 mA pulse current for gas sensing and LoRaWAN communication
Base Signal Scout Battery
Li/SOCl2, 3.6 VDC, 19000 mAh; stated 18 months at 25% duty cycle with minimum 5-minute ON duration
Base Signal Scout Dimensions
H 153.8 × D 120 mm, without adapter
Energy-Harvested Variant Dimensions
H 162.8 × D 120 mm, without adapter
Weight Including Mounting Adapter
Base Signal Scout: 500 g; Energy-Harvested variant: 530 g
Enclosure Rating
IP66 / IP67 / Type 4X
Mounting Options
Magnetic, screw, adhesive and epoxy-compatible adhesive mount adapters
Wireless Encryption
AES256 for LoRa and BLE
Honeywell Versatilis™ Signal Scout™ Methane Sensor — manufacturer page values
ParameterPublished value / configuration
Methane Sensing TechnologyMicroelectronic Spectroscopy (MES)
Methane Concentration Range50 to 65535 ppm
Methane Resolution1 ppm
Methane Response Time (T90)20 seconds with PTFE filter
Methane Accuracy±50 ppm at 50–300 ppm; ±10% above 300 ppm (manufacturer's stated conditions)
Gas Sampling Rate15 seconds
Operating Temperature−40 to +70 °C (−40 to +158 °F)
Ambient Pressure Measurement300 to 1100 hPa
Ambient Humidity Measurement0 to 100% RH
Pressure Sensor Accuracy0.5% of span
Humidity Sensor Accuracy±3% RH
Wireless Configuration2.4 GHz Bluetooth Low Energy 5.0
Long-Range CommunicationLoRaWAN Class A; EU868, US915, IN865 and AS923 regions
LoRaWAN ActivationABP or OTAA; Adaptive Data Rate supported
Electrical Supply3.6 VDC ±5%
Electrical Consumption1.5 mA, dependent on sensor duty cycle; 55 mA pulse current for gas sensing and LoRaWAN communication
Base Signal Scout BatteryLi/SOCl2, 3.6 VDC, 19000 mAh; stated 18 months at 25% duty cycle with minimum 5-minute ON duration
Base Signal Scout DimensionsH 153.8 × D 120 mm, without adapter
Energy-Harvested Variant DimensionsH 162.8 × D 120 mm, without adapter
Weight Including Mounting AdapterBase Signal Scout: 500 g; Energy-Harvested variant: 530 g
Enclosure RatingIP66 / IP67 / Type 4X
Mounting OptionsMagnetic, screw, adhesive and epoxy-compatible adhesive mount adapters
Wireless EncryptionAES256 for LoRa and BLE

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Published part numbers

1 parts

Part NumberDescriptionEnquiry
HVSS100Honeywell Versatili Signal Scout EDRequest quotation

Honeywell Versatilis Signal Scout (HVSS)

Battery-powered methane and ambient-condition sensing variant.

Dimensions without adapter
H 153.8 × D 120 mm
Weight including adapter
500 g

Honeywell Versatilis Signal Scout – Energy Harvested (HVSS-EH)

Published energy-harvested variant with PV-assisted power. Exact battery configuration follows the manufacturer selection guide.

Dimensions without adapter
H 162.8 × D 120 mm
Weight including adapter
530 g
Manufacturer sources

https://process.honeywell.com/us/en/products/field-instruments/iot-sensor-solutions/iot-gas-sensors/honeywell-versatilis-signal-scout-methane-sensor

Last source check: 2026-11-02

Honeywell Versatilis™ Signal Scout™ Methan Sensor Product Primary Image · Manufacturer ownership retained; republication licence not independently confirmed

Honeywell Versatilis™ Signal Scout™ Methan Sensor Product Secondary Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry