SmartLine Anytime Tool updates firmware across compatible SmartLine pressure, temperature and level instruments.

SmartLine Anytime Tool updates firmware across compatible SmartLine pressure, temperature and level instruments. Its PC software detects connected hardware and guides upgrades through a USB-powered interface. The kit also supports firmware changes needed when exchanging selected displays or communications modules, helping users retain newer functionality during instrument repairs and replacements.

Features & Benefits

Interface
USB connection to PC
Module connections
Five modules can be connected for upgrade
  • Shortens repair and replacement downtime

Applications

  • Firmware maintenance for compatible SmartLine instruments

Detailed capabilities

What Is It?

SmartLine Anytime Tool provides one firmware-upgrade platform for ST800/ST700 pressure, STT850/STT750 temperature and SLG700 level instruments. It also supports the described interchange of display and DE/HART/FF modules among selected instruments with the appropriate firmware work. That selection qualification matters: sharing the SmartLine name does not establish unrestricted interchangeability of every module.

Manufacturer reference ↗

How Does It Work?

The kit includes PC software and connects by USB without a separate power supply. Automatic device detection guides the upgrade, and five module ports permit concurrent connection for upgrading. Reverse module connection is supported, and a power indicator shows supply state. The workflow updates the detected hardware to the chosen firmware rather than reconfiguring process calibration by assumption.

Manufacturer reference ↗

What Problems Does It Solve?

A common upgrade tool reduces the number of maintenance tools and spare electronic variants that users must hold. Access to current firmware extends available functionality, while supported module reuse reduces repair/replacement interruption. The source connects these features with lower lifecycle cost and downtime, subject to the named instrument and module compatibility.

Manufacturer reference ↗

Product videos

Specifications

Functional & Control Features

Upgrade Capability
Supports firmware upgrades for all SmartLine devices

Application & Deployment

Supported Devices
Honeywell SmartLine: ST800/ST700 Pressure, STT850/STT750 Temperature, SLG700 Level Transmitters

Environmental Conditions

Relative Humidity
10 to 90% RH (Non-Condensing)

Software & Interface

Software Version
SmartLine Anytime Tool V1.00.XX volt
Operating System
Windows 7, 8, or 10

Electrical Specifications

Power Supply
260mA (+50) Current Consumption; USB Powered (5VDC, cable included)

Communication Interfaces

Interfaces
USB 2.0 (direct PC connection, no extra power supply needed)

Dimensions & Weight

Dimensions
160 H x 100 W x 26 mm D (6.3 x 3.94 x 1.02 in)

Standards & Certifications

Approvals
EMC Directive: EN 61326-1:2013, UL (Canada and USA): 61010-1

Others

Operating Temperature Range
-10 to +50 deg C; 14 to 122 deg F
Storage Temperature Range
-20 to +60 deg C; -4 to +140 deg F
SmartLine Anytime Tool — manufacturer page values
ParameterPublished value / configuration
Upgrade CapabilitySupports firmware upgrades for all SmartLine devices
Supported DevicesHoneywell SmartLine: ST800/ST700 Pressure, STT850/STT750 Temperature, SLG700 Level Transmitters
Relative Humidity10 to 90% RH (Non-Condensing)
Software VersionSmartLine Anytime Tool V1.00.XX volt
Operating SystemWindows 7, 8, or 10
Power Supply260mA (+50) Current Consumption; USB Powered (5VDC, cable included)
InterfacesUSB 2.0 (direct PC connection, no extra power supply needed)
Dimensions160 H x 100 W x 26 mm D (6.3 x 3.94 x 1.02 in)
ApprovalsEMC Directive: EN 61326-1:2013, UL (Canada and USA): 61010-1
Operating Temperature Range-10 to +50 deg C; 14 to 122 deg F
Storage Temperature Range-20 to +60 deg C; -4 to +140 deg F

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
32300458-501HART MODEM USBRequest quotation
32303995-501SAT TEMPERATURE SENSOR CABLERequest quotation
32303996-501SAT PRESSURE SENSOR CABLERequest quotation
32303997-501SAT DISPLAY MODULE CABLERequest quotation
32303998-501SAT USB CABLERequest quotation
32303999-501SAT CD-ROM (SAT SOFTWARE)Request quotation
32306657-501SAT LEVEL SENSOR CABLERequest quotation
32306658-501SAT COMMUNICATION MODULE CABLERequest quotation
50127236-501SAT CARRYING CASERequest quotation
50127238-501SAT TOOL FOR SMARTLINERequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/field-instruments/configuration-tools-and-software/smartline-anytime-tool

Last source check: 2026-11-02

SmartLine Anytime Tool Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry